Coastal Installation Considerations 
EverCore and PrimePower


Overview

Coastal environments can present unique challenges for outdoor electrical equipment. Salt-laden air, high humidity, and marine exposure can accelerate corrosion and impact the long-term performance of energy infrastructure.

To support reliable operation, the EverCore C&I Energy Storage System and PrimePower Energy Storage System incorporate advanced anti-corrosion protection designed for demanding outdoor environments. The systems feature C5/C5-M corrosion protection measures that help improve durability and protect critical components throughout the system lifetime.


Why Coastal Environments Require Special Consideration

Marine environments contain airborne salt particles that can be carried inland by wind and humidity. Over time, salt deposits on metal surfaces may increase the risk of corrosion and can accelerate the aging of outdoor equipment.

The severity of corrosion exposure depends on several factors, including:

  • Distance from the coastline
  • Prevailing wind direction
  • Humidity levels
  • Local topography
  • Environmental pollution

As a result, coastal installations often require additional consideration during the project planning phase.


SolisStorage Installation Guidance

For the EverCore and PrimePower product families, Solis recommends evaluating coastal locations carefully and installing systems at sites located more than 2 km from the coastline.

Distance from CoastlineGuidance
Less than 2 kmAdditional assessment may be required before installation
More than 2 kmSuitable for standard deployment, subject to site conditions

This guidance helps minimize exposure to the highest concentrations of airborne salt typically found in immediate coastal environments.

EverCore Product Page: check user manuals section: 5.1. Site Selection Requirements
PrimePower Product Page: check user manual section: 5.1. Requirements for the Site and Environment


Corrosion Protection for Long-Term Reliability

The EverCore platform combines corrosion protection with robust environmental design, including:

  • C5 anti-corrosion protection
  • IP55 cabinet protection
  • IP66 inverter protection
  • Industrial-grade components
  • Advanced thermal management architecture

These features help maintain system reliability and reduce maintenance requirements in demanding outdoor applications.

The PrimePower platform applies the same design philosophy to utility-scale energy storage projects, where long-term performance and operational availability are critical.


Best Practices for Coastal Projects

When planning an energy storage installation near coastal areas, Solis recommends:

  1. Evaluating the distance to the coastline.
  2. Assessing local environmental conditions such as humidity and prevailing winds.
  3. Ensuring the installation site complies with product installation requirements.
  4. Following all installation and maintenance recommendations provided in the applicable product documentation.

For projects in areas with elevated environmental exposure, additional site reviews may be required to determine the most appropriate solution.


Conclusion

The SolisStorage EverCore and PrimePower energy storage systems are designed with advanced corrosion protection to support reliable outdoor operation. While the systems incorporate C5/C5-M protection measures for demanding environments, Solis recommends installations are located more than 2 km from the coastline to reduce exposure to concentrated marine salt conditions and support long-term system performance.