summarized of locally DSP and HMI Update Procedures for Solis On-Grid Inverter

Modified on Fri, 8 Nov at 3:09 PM

This article is not available in Hebrew, view it in English

DSP Update Procedure

  1. Prepare USB Stick

    • Place 20862API.bin and 20862APP.bin files on a USB stick, ensuring 20862APP.bin is named correctly and not in a folder or zipped.
    • Ensure no other files are on the USB stick.
  2. Connect Firmware Update Tool

    • Insert USB into the Firmware Update Tool and connect to the inverter's 4-pin green port.
    • The tool should light up red and green.
  3. Inverter Settings

    • On the inverter display, go to Advanced Settings, enter password 0010, select "Turn Grid On/Off," and turn it OFF.
    • Return to Advanced Settings, enter the password again, and select DSP Update. Verify the current version.
  4. Initiate DSP Update

    • Select Enter on DSP Update. The green light on the tool should start flashing.
    • Press the button on the Firmware Update Tool to begin the update. Watch for the green light to flash rapidly, then slowly.
  5. Completion

    • When the green and red lights turn solid, the update is complete.
    • If the green light goes dark and then reappears after 4–5 seconds, the update was successful.
    • Verify the version change after the inverter’s LCD operation light stops blinking.
  6. Turn Grid Back On

    • In Advanced Settings, enter password 0010, select "Turn Grid On/Off," and turn it ON if production is ready.

HMI Update Procedure

  1. Prepare USB Stick

    • Place the HMI.bin or HMI_WIFI.bin file on a USB stick, ensuring it is named correctly and not zipped.
  2. Connect Firmware Update Tool

    • Insert the USB into the Firmware Update Tool and connect it to the inverter’s 4-pin Green Port. The tool should light up red and green.
  3. Inverter Settings

    • On the inverter display, go to Advanced Settings, enter password 0010, and turn the grid OFF.
    • Go back to Advanced Settings, enter password again, select HMI Update, and ensure no communication cables are connected, with the address set to 1.
  4. Initiate HMI Update

    • Hold the button on the Firmware Update Tool until all lights are lit, then release.
    • In Advanced Settings, select HMI Update and enter Update Mode. The screen will go blank, and the green light should flash.
    • Press the Firmware Update Tool button to start the update, verifying that the green light flashes quickly, then slowly.
  5. Completion

    • When the green light is solid, the update is complete.
    • If the green light briefly turns off and then reappears after 4–5 seconds, the update was successful.
    • Confirm the version change once the inverter LCD stops blinking.
  6. Turn Grid Back On

    • In Advanced Settings, enter password 0010, select "Turn Grid On/Off," and turn it ON if ready to resume production.

This summary captures the essential steps for updating DSP and HMI firmware on a Solis on-grid inverter. Following these instructions ensures the device remains updated and ready for optimal operation.

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article