Troubleshooting the LAN STICK




The 3 LEDs in LAN STICK are always on with LAN Stick.  



Below are how you read the LED status:



RESETTING THE LAN STICK


1: Open the outer cover

2: Connect the LAN to the operating inverter to give it power

3: Verify the lights come on

4: Hold Reset button for 5 seconds.  


CONNECTING TO THE LAN STICK


1: Connect LAN stick to operational inverter to provide power to LAN stick. Connect one end of an ethernet cable to LAN stick and other end directly to a computer.


2: On the computer, click on the Network Connections and select the Local Connection. Open the Local Connection Status, click on Properties, select internet protocol IPv4(TCP/IPv4).


3: Set a manual IP for the computer using the following information -

IP address :10.10.100.253

Subnet mask:255.255.255.0

Default gateway:10.10.100.100

Click - OK

(The IP of the computer must be with 10.10.100.XXX range to configure the LAN stick)


4: Once the computer IP is set with the above details open a web browser and navigate to 10.10.100.254 to login to LAN stick admin page.


Select Network, fill in the IP address assigned by the router/network administrator. Example below-


Verify the remote server A is Pingable:





If its not pingable ensure the following ports are set to allow data through router firewall


Firewall Details -

Ensure the following ports are set to allow data through router firewalls –

UK Server - 176.58.117.69 

data1.solarmanpv.com 

Ports - 10000, 80, 10010




Connect with Solis

 

LinkedIn Facebook Instagram YouTube Twitter




Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article